8/13/2020 0 Comments Baumuller Drive Fault Codes
You must possess JavaScript enabled in your browser to use the features of this site.IMS Supply is not an certified distributor, reseller or representative of Baumuller.All item names, art logos, brands and trademarks utilized on this site are the property of their respective owners and are usually used for id purposes only.
The position of your commute is supervised at all instances and any changes in the position will end up being indicated through the key pad. A fault is certainly a problem that halts the drive and there are usually two types of fault conditions. When this type of fault occurs, consumer settings can become set up that will immediately restart the get or actually wait for a established quantity of period and then attempt a restart if the mistake condition is usually no longer current. This kind of fault is more of a main mistake and may need even more in-depth analysis or actions such as push or electric motor repair. The trigger of the fault will have to become corrected before the problem can become reset to zero and the push started. The pursuing is a listing of the feasible fault requirements of the AIlen Bradley PowerFlex 40 drive and brief descriptions of the causes. Y2 Auxiliary Input Auxiliary insight interlock can be open Y3 Energy Loss DC bus voltage is usually below 85 of nominal N4 UnderVoltage DC shuttle bus voltage can be below minimal worth F5 OverVoltage DC tour bus voltage is definitely over optimum value Y6 Motor Stalled Travel is not capable to accelerate motor N7 Electric motor Overload Internal electronic overload journey Y8 Heatsink Overtemp Heatsink heat range exceeds fixed worth F12 HW OverCurrent The commute output present has surpassed the hardware current limit F13 Surface Mistake A present path to surface has become discovered at one or more output terminals F29 Analog Input Reduction A sign reduction at an analog insight has happened F33 Auto Restart Tries Drive failed to reset a fault and resume running F38 Stage U to Surface A phase to floor fault has been recognized in this phase F39 Stage Sixth is v to Floor A phase to terrain fault has been discovered in this phase N40 Stage Watts to Ground A stage to surface fault has been discovered in this stage F41 Phase UV Brief Excessive present has become detected between these two output terminals F42 Stage UW Brief Excessive present has happen to be detected between these two result terminals F43 Phase VW Brief Excessive current has ended up recognized between these two output terminals F48 Parameters Defaulted Get was instructed to write default ideals to EEPROM F63 SW OverCurrent Programmed current trip has been surpassed F64 Drive Overload Commute ranking of 150 for 1 minute or 200 for 3 secs exceeded F70 Energy Unit Failing has ended up recognized in the commute power section Y71 Online Reduction The communication network has faulted N80 SVC Autotune Autotune functionality has neglected or had been terminated by the user F81 Comm Reduction RS485 (DSI) slot has ceased communicating Y100 Parameter Checksum The checksum learn does not complement the checksum calculated N122 IO Plank Fail Failing has become detected in the get control and IO area. ![]() If the mistake can not be healed, contact on the Allen Bradley fix specialists at Accuracy Electronic Providers, Inc. ![]() The device is operating good and your company has produced it in my black reserve and rolodex ás my go-tó for upcoming maintenance.
0 Comments
Leave a Reply. |
AuthorWrite something about yourself. No need to be fancy, just an overview. ArchivesCategories |